SCIENTIFIC INSTRUMENTATION


LIQUID TRANSFERS

ExperimentSampleManipulation[]

Example applications include: Robotic Liquid Handling, Manual Liquid Handling, Sample Heating, Sample Chilling, Sample Mixing, Sample Centrifugation, Magnetic Bead Separation, Positive Pressure Filtration, Solid Phase Extraction, Absorbance Measurement, Fluorescence Measurement, Luminescence Measurement

Robotic Sample Preparation Workcell

 

Workcell Integrated Micro Liquid Handler

Large Capacity Deck

  • 4x heater/shaker plate positions
    • heating up to 105°C
    • shaking up to 2,500 RPM
  • 4x heater/cooler plate positions
    • heating up to 110°C
    • cooling down to 0°C
  • 12x SBS plate positions (including any deep well or microtiter plates)
  • 12x 50 mL conical tube positions
  • 64x microcentrifuge tube or CE/HPLC vial positions
  • Compatible with a wide variety of tubes (including opaque tubes for light sensitive samples)
  • Robotic arm for movement of plates, lids, and racks around the deck and to/from integrations

8x Independent Single Channel Pipettes

  • 1 μL to 1 mL volume (± 1%)
  • 0.4 to 250 μL/sec aspirate/dispense rate
  • 10 μL, 50 μL, 300 μL, 1,000 μL regular, widebore, and filtered disposable polypropylene tips
  • Pre-aspiration/post-dispense mixing
  • Fine-grained pipette tip aspiration and dispense position control
  • Tip movement and speed control

1x Multichannel Pipette (96 Channels)

  • Capable of any simultaneous rectangular pipetting up to dimensions 8×12
  • 1 μL to 1 mL volume (± 2%)
  • 0.4 to 250 μL/sec aspirate/dispense rate
  • 10 μL, 50 μL, 300 μL, 1,000 μL regular, widebore, and filtered disposable polypropylene tips
  • Pre-aspiration/post-dispense mixing
  • Fine-grained pipette tip aspiration and dispense position control
  • Tip movement and speed control
Hamilton Star

Workcell Integrated Pressure Filter

  • 0 to 40 PSI independent pressure sources for each well
  • Filter though SBS filter plates
  • Collects in SBS deep well plates
Hamilton MPE2

Workcell Integrated Plate Reader

  • Supports absorbance, fluorescence, and luminescence reads

Absorbance

  • CCD detector
  • 220 to 1,000 nm wavelength selection

Excitation

  • Xenon flash lamp
  • 1 to 100 flashes per well
  • 320 to 740 nm excitation monochromator (8 nm bandpass)
  • 680 nm laser (AlphaScreen)

Emission

  • High voltage PMT detector
  • 320 to 850 nm emission monochromator (8 nm bandpass)

Sample Injection

  • 2x 500 µL injection syringes per batch
  • 50 µL dead volumes, 0.5 µL precision
  • 25 mL/min maximum injection speed
  • 2 mL microcentrifuge tubes, 15 mL conical tubes, or 50 mL conical tube sources

Sample Chamber

  • Room temperature (25°C ± 0.45°C (1 sigma)) to 45°C incubation
  • Mix by shaking before read options
  • 1x microtiter plate (6 to 96 well) per batch

Workcell Integrated Pressure Filter

  • 3,000 RPM maximum speed (1,000 x g at Rmax)
  • 250 x g maximum payload per bucket
  • 10 g maximum imbalance
  • 2 SBS plate footprint buckets
  • 48.3 mm max plate height
Agilent Microplate Centrifuge

 

ExperimentAcousticLiquidHandling[]

Example applications include: Small Volume Transfer, Nanoliter Transfer, Acoustic Droplet Ejection, Contactless Liquid Transfer

Acoustic Liquid Handler

  • Contact-free tipless liquid transfer
  • 2.5 nL to 5 µL volume (± 10%)
  • Dispense from 384-well Echo Qualified plates into any 96- or 384- shallow well SBS-format plates
  • Fine-grained dispense position control allowing multiple distinct droplets per well
  • Dispenses up to 200 droplets (500 nL) per second
  • Rapid high-precision dispensing of small volumes of liquids
  • Capable of handling high-viscosity aqueous solutions
Labcyte Echo 650

ExperimentTransfer[]

Example applications include: Creating Standard Curves, Serial Dilutions, and Aliquots

Micropipettes

  • Reverse pipetting available
  • Aspiration dispense mixing (slurry transfers)
  • Gravimetric transfers
    • Liquids can be transferred by weight (gravimetrically), from µg to kg, in both sterile and non-sterile environments
  • Temperature controlled transfers
    • Temperature-sensitive source/destination samples can be marked to be chilled (4ºC) or heated (30 to 105ºC) during transfers (for more information, see Sample Transport section)
  • Single-channel pipettes
    • 0.1 to 2.5 µL
    • 2 to 20 µL
    • 20 to 200 µL
    • 100 to 1,000 µL
    • 0.5 to 5 mL
  • Compatible tip types
    • 10 μL reach tips, sterile
    • 20 μL barrier tips, sterile
    • 200 μL gel loading tips
    • 200 μL tips, non-sterile
    • 200 μL tips, sterile
    • 200 μL wide-bore tips, non-sterile
    • 1,000 μL wide-bore tips, non-sterile
    • 1,000 μL reach tips, sterile
    • 1,000 μL tips, non-sterile
    • 5,000 μL tips, non-sterile
Single channel pipettes
Tips

Positive Displacement Pipettes

  • Reverse pipetting available
  • Aspiration dispense mixing (slurry transfers)
  • Gravimetric transfers
  • Temperature controlled transfers
  • Temperature-sensitive source/destination samples can be marked to be chilled (4ºC) or heated (30 to 105ºC) during transfers (for more information, see Sample Transport section)
  • Positive-Displacement Pipette MR-100
    • Min volume: 10 µL
    • Max volume: 100 µL
  • Positive-Displacement Pipette MR-1000
    • Min volume: 100 µL
    • Max volume: 1 mL
  • Compatible and supported tips
    • 100 µL positive displacement tips, sterile
    • 1,000 µL positive displacement tips, sterile
Rainin Pos-d Mr-100, Mr-1000

Serological Pipettes

  • Reverse pipetting available
  • Aspiration dispense mixing (slurry transfers)
  • Gravimetric transfers
    • Liquids can be transferred by weight (gravimetrically), from µg to kg, in both sterile and non-sterile environments
  • Temperature controlled transfers
    • Temperature-sensitive source/destination samples can be marked to be chilled (4ºC) or heated (30 to 105ºC) during transfers (for more information, see Sample Transport section)
  • Variable dispense/aspirate speed (8 settings)
  • 15 hours of continuous operation before recharging
  • Compatible plastic serological pipette tips
    • 2 mL plastic barrier serological pipettes, sterile
    • 5 mL plastic barrier serological pipettes, sterile
    • 10 mL plastic barrier serological pipettes, sterile
    • 25 mL plastic barrier serological pipettes, sterile
    • 50 mL plastic barrier serological pipettes, sterile
  • Compatible glass serological pipette tips
    • 1 mL glass barrier serological pipettes, sterile
    • 2 mL glass barrier serological pipettes, sterile
    • 5 mL glass barrier serological pipettes, sterile
    • 10 mL glass barrier serological pipettes, sterile
    • 25 mL glass barrier serological pipettes, sterile
    • 50 mL glass barrier serological pipettes, sterile
S1 Pipette Filler
Plastic Tips
Glass Tips

Syringes

  • 1 to 60 mL max volume
  • 2 different connection types: Luer-Lok and Luer-Slip
  • Polyethylene barrel and polypropylene plunger syringes
  • Luer-Slip
    • 1 mL disposable syringe
    • 50 mL disposable Luer-Slip syringe
  • Luer-Lok
    • 3 mL sterile disposable syringe
    • 5 mL sterile disposable syringe
    • 10 mL Luer-Lok syringe
    • 20 mL disposable Luer-Lok syringe
    • 60 mL sterile disposable syringe
  • Needles
    • 21 G x 1 in stainless steel single-use needle
    • 18 G x 4 in reusable stainless steel non-coring needle
    • 18 G x 6 in reusable stainless steel non-coring needle
    • 18 G x 12 in reusable stainless steel non-coring needle
Syringes
Needles

Syringe Pump

  • Dual syringes for continuous dispensing at constant flow rates for up to 72 hours
  • Multiple syringes to choose from: 10 µL, 50 µL, 500 µL, 50 mL
    • Borosilicate glass, PTFE, PFA Fluid Path
    • Minimum flow rate of 0.003 µL/sec (10µL syringe)
    • Maximum flow rate of 6000 µL/sec (50mL syringe)
  • Syringes attach to 12 or 18 gauge tubing and luer-lock
  • Available in multipe transfer environments (BSC, Glove Box, Fume Hood, Lab Bench)
Microlab 635 Dual Syringe

Graduated Cylinders

  • Transfers of liquids and slurries
  • Optional overhead mixing/heating during addition
  • Cylinders
    • 10 mL glass
    • 25 mL polypropylene
    • 50 mL polypropylene
    • 100 mL polypropylene
    • 250 mL polypropylene
    • 500 mL polypropylene
    • 1 L polypropylene
    • 2 L polypropylene
    • 4 L polypropylene
Graduated Cylinders

Ampoule Handling

  • 1 to 2 mL
  • 5 to 15 mL
  • 20 to 30 mL
Ampoule Breaker

Cell Aspirators

Handheld vacuum-aspirator with interchangeable adapter heads

  • Pressure-sensitive button controls amount of vacuum applied to aspirate sample
  • Adapter heads accept single-use, disposable tips and contain ejectors to exchange tips
  • All parts may be autoclaved

Available adapter heads

  • 8-channel head compatible with 200 µL pipette tips
  • Single channel head compatible with disposable 2 mL aspirating pipettes
Argos Technologies Handheld Waste-disposal system.

Argos Technologies Handheld Waste-disposal system.