SEPARATIONS
ExperimentHPLC[]
UNDER DEVELOPMENT
Example applications include: Protein purification, Carbohydrate and oligosaccharides analysis, Polynucleotide separation, trace impurity analysis, Liquid chromatography, Affinity chromatography, Ion-exchange chromatography, Size exclusion chromatography, Reverse phase chromatography, Normal phase chromatography, Chiral chromatography
Analytical HPLC with Photo Diode Array and Fluorescence Detector
Quaternary Pump
- 0.1 to 2.2 mL/min flow rate
- 7,000 PSI maximum pressure
- 0.01 inch inner diameter PEEK system tubing
- Dynamic mixer
- In-line degasser
- Titanium pump casing with sapphire pump heads
- 250 mL to 5 L buffer source bottles/carboys
Detectors
- Absorbance diode array (PDA)
- Deuterium lamp
- 190 to 500 nm absorbance detection (1.2 nm resolution)
- Quartz flow cell
- 10 mm pathlength
- 0.5 µL volume
- 1,000 PSI maximum pressure
Column Oven
- 20 to 90°C (± 0.1°C) incubation
- Up to 2 columns connected in series per run
- 300 mm maximum column length
- 15 mm maximum column outer diameter
Sample Constraints
- 75 µL sample loop
- 250 µL autosampler syringe
- Sample chamber temperature controlled from 5 to 40°C (± 3°C)
- Up to 48x HPLC/CE vials or 2x SBS style deep well plates per batch
Analytical HPLC with Evaporative Light Scattering Detector
Quaternary Pump
- 0.1 to 2.2 mL/min flow rate
- 7,000 PSI maximum pressure
- 0.01 inch inner diameter PEEK system tubing
- Dynamic mixer
- In-line degasser
- Titanium pump casing with sapphire pump heads
- 250 mL to 5 L buffer source bottles/carboys
Detectors
- Ultraviolet absorbance
- Deuterium lamp
- 190 to 700 nm wavelength range
- Fused silica flow cell with 10 mm pathlength
- 0.5 µL volume
- 1,000 PSI maximum pressure
- Up to 80 points/second sampling rate
- Evaporative Light Scattering (ELS)
- Nitrogen sheath gas
- Flow rate between 20 and 60 PSI
- Heatable to varying magnitude
- 2 mL/min maximum flow rate
- Up to 80 points/second sampling rate
- Drift tube up to 100°C
- Tungsten halogen light source
- Nitrogen sheath gas
Column Oven
- 20 to 90°C (± 0.1°C) incubation
- Up to 2 columns connected in series per run
- 300 mm maximum column length
- 15 mm maximum column outer diameter
Sample Constraints
- 75 µL sample loop
- 250 µL autosampler syringe
- Sample chamber temperature controlled from 5 to 40°C (± 3°C)
- Up to 48x HPLC/CE vials or 2x SBS style deep well plates per batch
Semi-Preparative HPLC with UV/Vis Detector
Quaternary Pump
- 0.2 to 8 mL/min flow rate
- 300 PSI minimum pressure
- 4,000 PSI maximum pressure
- 0.01 inch inner diameter PEEK system tubing
- Static mixer
- In-line degasser
- Titanium pump casing with sapphire pump heads
- 250 mL to 20 L buffer source bottles/carboys
Detectors
- Pump pressure sensor
- Column temperature sensor
- Absorbance diode
- Tungsten deuterium lamp
- 190 to 900 nm monochromator
- 6 nm bandpass
- Quartz flow cell
- 10 mm pathlength
- 11 µL volume
- 725 PSI maximum pressure
Column Oven
- 5 to 80°C (± 0.1°C) incubation
- 300 mm maximum column length
- 25 mm maximum column outer diameter
Fraction Collection
- Absorbance-based fraction collection methods
- Absolute threshold
- Derivative detection
- Time based
- Up to 8x 96-well deep well plate fraction containers per batch
Sample Constraints
- 500 µL sample loop
- 500 µL autosampler syringe
- Up to 40x HPLC/CE vials or 2x SBS style deep well plates per batch
Semi-Preparative HPLC with pH/Conductivity, UV/Vis, and Fluorescence Detectors
- 0.2 to 8 mL/min flow rate
- 300 PSI minimum pressure
- 4,000 PSI maximum pressure
- 0.01 inch inner diameter PEEK system tubing
- Static mixer
- In-line degasser
- Titanium pump casing with sapphire pump heads
- 250 mL to 20 L buffer source bottles/carboys
Quaternary Pump
Detectors
- Pump pressure sensor
- Column temperature sensor
- Absorbance diode
- Tungsten deuterium lamp
- 190 to 900 nm monochromator
- 6 nm bandpass
- Quartz flow cell
- 10 mm pathlength
- 11 µL volume
- 725 PSI maximum pressure
- Fluorescence
- 8 µL flow cell volume
- 290 PSI maximum pressure
- 200 to 880 nm for excitation light (xenon flash lamp source)
- 220 to 900 nm for emission light
Column Oven
- 5 to 80°C (± 0.1°C) incubation
- 300 mm maximum column length
- 25 mm maximum column outer diameter
Fraction Collection
- Absorbance-based fraction collection methods
- Absolute threshold
- Derivative detection
- Time based
- Up to 8x 96-well deep well plate fraction containers per batch
Sample Constraints
- 500 µL sample loop
- 500 µL autosampler syringe
- Up to 40x HPLC/CE vials or 2x SBS style deep well plates per batch
Semi-Preparative HPLC with MALS, DLS, and RI Detector
Quaternary Pump
- 0.2 to 8 mL/min flow rate
- 300 PSI minimum pressure
- 4,000 PSI maximum pressure
- 0.01 inch inner diameter PEEK system tubing
- Static mixer
- In-line degasser
- Titanium pump casing with sapphire pump heads
- 250 mL to 20 L buffer source bottles/carboys
Detectors
- Pump pressure sensor
- Column temperature sensor
- Absorbance diode
- Tungsten deuterium lamp
- 190 to 900 nm monochromator
- 6 nm bandpass
- Quartz flow cell
- 10 mm pathlength
- 11 µL volume
- 725 PSI maximum pressure
- Multi-angle light scattering
- Up to 36.6 points/sec sampling rate
- 200 Da to 1,000 MDa molar mass range
- 0.5 to 500 nm radius of gyration measurement range
- Light scattering detectors at 18 angles
- 658 nm laser wavelength
- Operating temperature between -15 and 150°C
- Dynamic light scattering
- Up to 36.6 points/sec sampling rate
- 0.5 to 30 nm hydrodynamic radius measurement range
- Refractive Index detector
- 7.4 µL flow cell volume
- Absolute Refractive Index (RI) measurement mode and Differential Refractive Index (DRI) measurement mode available
- 1.2 to 1.8 RIU Absolute Refractive Index range
- 0.002 RIU Absolute Refractive Index sensitivity
- -0.0047 to +0.0047 RIU Differential Refractive Index range
- ± 7.5 x 10e-10 RIU Differential Refractive Index sensitivity
- Temperature range 4 and 65°C
- 660 nm light source
- Dynamic Range > 16,000,000
Column Oven
- 5 to 80°C (± 0.1°C) incubation
- 300 mm maximum column length
- 25 mm maximum column outer diameter
Fraction Collection
- Absorbance-based fraction collection methods
- Absolute threshold
- Derivative detection
- Time based
- Up to 8x 96-well deep well plate fraction containers per batch
Sample Constraints
- 500 µL sample loop
- 500 µL autosampler syringe
- Up to 40x HPLC/CE vials or 2x SBS style deep well plates per batch
Semi-Preparative HPLC with MALS, DLS, and RI Detector
Quaternary Pump
- 0.2 to 8 mL/min flow rate
- 300 PSI minimum pressure
- 4,000 PSI maximum pressure
- 0.01 inch inner diameter PEEK system tubing
- Static mixer
- In-line degasser
- Titanium pump casing with sapphire pump heads
- 250 mL to 20 L buffer source bottles/carboys
Column Oven
- 5 to 80°C (± 0.1°C) incubation
- 300 mm maximum column length
- 25 mm maximum column outer diameter
Detectors
- Absorbance diode
- Tungsten deuterium lamp
- 190 to 900 nm monochromator
- 6 nm bandpass
- Quartz flow cell
- 10 mm pathlength
- 11 µL volume
- 725 PSI maximum pressure
- Multi-angle light scattering
- Up to 36.6 points/sec sampling rate
- 200 Da to 1,000 MDa molar mass range
- 0.5 to 500 nm radius of gyration measurement range
- Light scattering detectors at 18 angles
- 658 nm laser wavelength
- Operating temperature between -15 and 150°C
- Refractive Index detector
- 7.4 µL flow cell volume
- Absolute Refractive Index (RI) measurement mode and Differential Refractive Index (DRI) measurement mode available
- 1.2 to 1.8 RIU Absolute Refractive Index range
- 0.002 RIU Absolute Refractive Index sensitivity
- -0.0047 to +0.0047 RIU Differential Refractive Index range
- ± 7.5 x 10e-10 RIU Differential Refractive Index sensitivity
- Temperature range 4 and 65°C
- 660 nm light source
- Dynamic Range > 16,000,000
- Different viscometer detector
- Minimum detectable sample at 0.1 µg of 100 kDa polystyrene in THF at 1 mL/min
- 6.9 kPa differential pressure range
- 13,500:1 dynamic range
- Up to 1.5 mL/min for aqueous sample and 3 mL/min for THF
- 4 ºC to 70 ºC temperature control
Fraction Collection
- Absorbance-based fraction collection methods
- Absolute threshold
- Derivative detection
- Time based
- Up to 8x 96-well deep well plate fraction containers per batch
Sample Constraints
- 500 µL sample loop
- 500 µL autosampler syringe
- Up to 40x HPLC/CE vials or 2x SBS style deep well plates per batch
Large Scale Preparative HPLC with UV/Vis Detector
Binary Pump
- Up to 50 mL/min flow rate
- 6,000 PSI maximum pressure
- In-line degasser
- 2 to 20 L buffer source bottles/carboys
Column Selector
- Ambient temperature
- Switchable for up to 6 columns
Detectors
- Pump pressure sensor
- Column temperature sensor
- Ultraviolet absorbance detector
- Deuterium lamp
- 190 to 600 nm wavelength range (up to two channels)
- 1 nm wavelength bandpass
- Up to 120 samples/second measurement (25 samples/second for dual channel) – Quartz flow cell 3 mm pathlength – 4 µL volume – 1,760 PSI maximum pressure
Fraction Collection
- Absorbance-based fraction collection methods
- Absolute threshold
- Derivative detection
- Time based
- Up to 8x 96-well deep well plate fraction containers per batch
Sample Constraints
- 500 µL sample loop
- 500 µL autosampler syringe
- Up to 40x HPLC/CE vials or 2x SBS style deep well plates per batch
Analytical HPLC with Refractive Index Detector
Semi-Preparative HPLC with UV/Vis Diode Array + Access for 3rd party detectors
Semi-Preparative HPLC with UV/Vis Diode Array + Fluorescence Detectors
Semi-Preparative HPLC with UV/Vis Diode Array Detector
Binary Pump
- Up to 50 mL/min flow rate
- 6,000 PSI maximum pressure
- In-line degasser
- 2 to 20 L buffer source bottles/carboys
Column Selector
- Ambient temperature
- Switchable for up to 6 columns
Detectors
- Pump pressure sensor
- Column temperature sensor
- Ultraviolet absorbance detector
- Deuterium lamp
- 190 to 600 nm wavelength range (up to two channels)
- 1 nm wavelength bandpass
- Up to 120 samples/second measurement (25 samples/second for dual channel) – Quartz flow cell 3 mm pathlength – 4 µL volume – 1,760 PSI maximum pressure
Fraction Collection
- Absorbance-based fraction collection methods
- Absolute threshold
- Derivative detection
- Time based
- Up to 8x 96-well deep well plate fraction containers per batch
Sample Constraints
- 500 µL sample loop
- 500 µL autosampler syringe
- Up to 40x HPLC/CE vials or 2x SBS style deep well plates per batch
Analytical HPLC with Refractive Index Detector
Binary Pump
- Up to 50 mL/min flow rate
- 6,000 PSI maximum pressure
- In-line degasser
- 2 to 20 L buffer source bottles/carboys
Column Selector
- Ambient temperature
- Switchable for up to 6 columns
Detectors
- Pump pressure sensor
- Column temperature sensor
- Ultraviolet absorbance detector
- Deuterium lamp
- 190 to 600 nm wavelength range (up to two channels)
- 1 nm wavelength bandpass
- Up to 120 samples/second measurement (25 samples/second for dual channel) – Quartz flow cell 3 mm pathlength – 4 µL volume – 1,760 PSI maximum pressure
Fraction Collection
- Absorbance-based fraction collection methods
- Absolute threshold
- Derivative detection
- Time based
- Up to 8x 96-well deep well plate fraction containers per batch
Sample Constraints
- 500 µL sample loop
- 500 µL autosampler syringe
- Up to 40x HPLC/CE vials or 2x SBS style deep well plates per batch
Semi-Preparative HPLC Viscometer
Differential Viscosity
- Sensitivity (minimum detectable sample): 0.1 μg of 100 kDa polystyrene in THF at 1 mL/min, under typical GPC conditions
- Differential pressure noise: < 0.05 Pa
- Differential pressure range: 6.9 kPa, protected against overpressure
- Dynamic range: 135,000:1
- Linearity: 0.5% of full scale
- Differential pressure drift: < 2.5 Pa/hr
- Capillary bridge autobalance: Thermal, leak-free mechanism
- Sample shear rate: 5000 Hz with water at 1 mL/min
Fluidics
- Max. flow rate: Aqueous: 1.5 mL/min; THF: 3 mL/min
- Delay volume options: 16.2, 10.8 or 5.4 mL, with additional factory-installed option for 32.4 mL 1
- Max. permissible pressure inlet to outlet: 690 kPa
- Wetted Materials: 316 stainless steel, PTFE, zirconium silicate, Kalrez ® , Inconel, 26-1 Stainless Steel
Temperature Control
- Range: 4 ºC to 70 ºC
- Stability: <0.005°C
- Ambient Range: 0 ºC to 40 ºC, 20% to 70% RH
Electronics
- Digital Output 20 bits @ 10 Hz
- Auxiliary I/O
- Inputs: Autoinject contact closure, Alarm In, Analog In: 2 differential inputs, 18 bits resolution, range -10 V to +10 V
- Outputs: Autoinject Retransmit, Alarm Out, Recycle Out
- On-board Computer
- Communications Ethernet
- Front Panel Display: 7″ (178 mm), high-resolution, multi-touch display for viewing/setting signals, instrument settings and diagnostics.
- Dimensions: 58 cm (L) x 36 cm (W) x 18 cm (H)
ExperimentGasChromatography[]
Gas Chromatography System
Flow System
- He carrier gas available
- Inlets available:
- Split/Splitless capillary column inlet
- Multimode temperature-programmable capillary column inlet
- Column head pressure up to 100 PSIG
Column Oven
- Temperature range: 30 to 450ºC
- Up to 120ºC/min temperature ramp
- Up to 2 capillary columns
- 0.53 mm maximum column inner diameter
Split/Splitless Capillary Inlet
- Suitable for capillary columns up to 0.53 mm inner diameter
- Split ratio up to 7,500:1 to prevent column overload
- Up to 1,250 mL/min total flow of He
- Inlet temperature 30 to 400ºC
Multimode Capillary Inlet
- Suitable for capillary columns up to 0.53 mm inner diameter
- Split ratio up to 7,500:1 to prevent column overload
- Up to 1,250 mL/min total flow of He
- Inlet temperature 30 to 400ºC
- Temperature programmable with ramp rates up to 900ºC/min
Mass Spectrometry
- Single quadrupole mass spectrometer
- 1.6 to 1,050 m/z mass range
- 100 to 200ºC quadrupole temperature
- 100 to 300ºC ion source temperature
- 100 to 350ºC transfer line temperature
- Scan speeds up to 12,500 m/z per second
- Electron ionization:
- Dual filaments
- Chemical ionization:
- Single filament
- Methane reagent gas
- Positive and negative mode
Flame Ionization Detector
- Responds to most organic compounds
- Minimum detectable level (for tridecane): < 1.2 pgC/s
- Linear dynamic range: > 10⁷ (± 10%)
- Up to 1,000 points/second data measurement
Autosampler Rail System
- Vortex mixing up to 2,000 RPM
- Sample incubation 30 to 200ºC
- Liquid, headspace, and solid-phase microextraction sample preparation available
- 0.01 to 100 µL injection volumes for liquid injection
- 25 to 2,500 µL injection volumes for headspace injection
- Headspace syringe heating 40 to 150ºC
ExperimentIonChromatography[]
Ion Chromatography System
Pumps
- Dual channel system
- Anion Channel: Isocratic pump with pure water being primary solvent
- Cation Channel: Quaternary pump
- 0.1 to 10 mL/min flow rate
- 5,000 PSI maximum pressure
- Static mixer
- In-line degasser
Eluent Generator
- Electrolytic eluent generation for anionic applications
- 0.1 to 100 mM concentration
Dynamically Regenerated Suppressors
- Constant voltage and constant current mode
- Maximum suppressor capabilities:
- Anion channel: 50 μeq/min
- Cation channel: 35 μeq/min
- 0.25 to 0.75 mL/min flow rate
Conductance Detectors
- Passivated 316 stainless steel electrode
- Maximum range up to 15,000 μS conductance measurement
- 0.7 µL flow cell volume
- One detector for each channel
- Shared detection oven with 15 to 60ºC (± 0.5ºC) incubation
Column Oven
- 10 to 70°C (± 0.1°C) incubation
- One analytical column for each channel
Sample Constraints
- 10 µL sample loops
- Up to 40x HPLC/CE vials or 2x SBS style deep well plates per batch
- Sample chamber temperature controlled from 4 to 60°C
Ion Chromatography System with Electrochemical Detector
Quaternary Pump
- Single channel system
- 0.1 to 10 mL/min flow rate
- 5,000 PSI maximum pressure
- Static mixer
- In-line degasser
Ultraviolet absorbance detector
- Tungsten and Deuterium lamp
- 190 to 900 nm wavelength range (up to four channels)
- 6 nm wavelength bandpass
- Up to 100 samples/second measurement
- PEEK flow cell
- 10 mm path length
- 11 μL flow cell volume
Electrochemical detector
- < 0.2 μL internal volume
- 100 PSI maximum pressure
- Gold, platinum, carbon and silver working electrodes
- pH-Ag/AgCl reference electrode
Column Oven
- 10 to 70°C (± 0.1°C) incubation
Sample Constraints
- 25 μL sample loop
- Up to 40x HPLC/CE vials or 2x SBS style deep well plates per batch
- Sample chamber temperature controlled from 4 to 60°C
ExperimentFPLC[]
Example applications include: Aqueous mobile phase, Protein purification, Biomolecule purification, Fast protein liquid chromatography, Medium-pressure chromatography, Liquid chromatography, Affinity chromatography
Fast Protein Liquid Chromatography System Medium and High Flow
System Pump & Mixer
- 0.001 to 25 mL/min flow rate (50 mL/min for column packing) for Avant 25
- 0.001 to 150 mL/min flow rate (300 mL/min for column packing) for Avant 150
- 20 MPa maximum pressure for Avant 25
- 5 MPa maximum pressure for Avant 150
- 1.4 L mixer volume
- ± 0.6% gradient composition accuracy for Avant 25
- ± 0.8% gradient composition accuracy for Avant 150
Detectors
- Pump pressure sensor
- 0 to 20 MPa range
- ± 0.02 MPa accuracy
- Temperature monitor
- ± 1.5°C temperature accuracy
- Conductance sensor
- 0.01 mS/cm to 1 S/cm conductance range
- 22 µL flow cell volume
- Absorbance monitor
- 190 to 700 nm wavelength range in increments of 1 nm wavelength
- Up to 3 simultaneous wavelengths
- UV flow cell
- 0.5 mm, 2 mm, or 10 mm pathlengths
- 1 μL, 2 μL, or 8 μL volumes
- Noise < 0.08 mAU
- pH monitor
- 0 to 14 range
- ± 0.1 pH unit (within pH 2 to 12)
Fraction Collection
- Absorbance-based or conductivity-based fraction collection methods
- Absolute threshold
- Derivative detection
- Time based
- Start collection with sample application or within the gradient
- 50 mL container, 15 mL container, or 96-well deep well plate fraction collection
Sample Constraints
- Autosampler mode
- 50 to 10,000 µL sample loop volume
- 1,000 to 10,000 µL autosampler syringe
- Up to 168x HPLC/CE vials or 2x SBS style deep well plate per batch
- Up to 12 large sample vials (10 mL) for preparative system
- Flow injection mode
- Up to 50 mL to 4 L sample container volumes
- Up to 5 containers
- Controllable sample introduction rate (up to 150 mL/min)
- Superloop mode
- 10 mL loop volume
- Up to 50 mL to 4 L sample container volumes
- Up to 5 containers
ExperimentFlashChromatography[]
Flash Chromatography System
Binary Pump
- 500 to 200 mL/min flow rate
- 200 PSI maximum pressure
- Up to 20 L drum solvent sources
- Programmable gradient (± 1% accuracy)
Absorbance Detector
- Deuterium lamp
- 200 nm and 780 nm UV detection (5 nm bandpass)
- 0.6 µl flow cell (0.1 mm pathlength)
Fraction Collection
- 30x 50 mL vials per batch
- 70x 25 mL vials per batch
Column Constraints
- Luer lock connector pre-packed columns
- Up to 70 mm outer diamter flash columns
- Up to 16.5″ length flash columns
- ~5 to ~660 g of resin per column
Sample Constraints
- Up to 33 g of solid material for dry loading
- Up to 50 mL of liquid material for wet loading
ExperimentPAGE[]
ExperimentAgaroseGelElectrophoresis[]
Robotic Gel Electrophoresis System
Polyacrylamide Gel Electrophoresis
- Slab Gels
- 4.5% and 10% TBE-Urea gels
- 10% TBE gels
- 7% and 12% Tris-Glycine gels
- 5 mm width lanes
- 3 mm depth gels
- Electrophoresis
- 0 to 125 V
- 1 to 100% duty cycle options
- Fluorescence Imaging
- Post stained gels (stained with any custom solution)
- Excitation filters
- 470 nm (70 nm bandpass)
- 625 nm (70 nm bandpass)
- Emission filters
- 540 nm (40 nm bandpass)
- 678 nm (44 nm bandpass)
- Sample Constraints
- Up to 20 µL of sample and loading buffer per lane
- Up to 10 lanes per gel
- Up to 4 gels per batch
Agarose Gel Electrophoresis
- Gels
- Analytics (no sample recovery) or size selection (targeted recovery of analytes of particular sizes)
- 0.5, 1.0, 1.5, 2.0, and 3.0% agarose
- Independent lanes
- Electrophoresis
- 100 V
- 1 to 100% duty cycle options
- Fluorescence Imaging
- Pre-stained markers ranging from 25 to 20,000 base pairs
- Multiple in-run images
- Excitation filters
- 470 nm (70 nm bandpass)
- 625 nm (70 nm bandpass)
- Emission filters
- 540 nm (40 nm bandpass)
- 678 nm (44 nm bandpass)
- Sample Constraints (Size Selection)
- Up to 50 µL of sample and loading buffer per lane
- Up to 12 lanes per gel
- Up to 4 gels per batch
- Sample Constraints (Analytical)
- Up to 8 µL of sample and loading buffer per lane
- Up to 23 lanes per gel
- Up to 4 gels per batch
ExperimentWestern[]
ExperimentTotalProteinDetection[]
Example applications include: Capillary-based Analytical Assay, Gel Electrophoresis, Capillary Gel Electrophoresis, Total Protein Separation, Total Protein Visualization, Protein Size Characterization, Protein Abundance Comparison
Capillary Western Blot System
Capillary Gel Electrophoresis
- 2 to 440 kDa molecular weight range
- 0 to 500 V separation voltage
- UV capillary crosslinking for protein immobilization
Secondary Antibodies Available
- Secondary Antibodies Available
- Goat Anti-Rabbit HRP
- Goat Anti-Mouse HRP
- Goat Anti-Human IgG HRP
- Donkey Anti-Goat HRP
CCD Camera-Based Capillary Imaging
- 100 ms to 512 sec exposure times
- Up to picogram sensitivity (depending on the primary antibody sensitivity)
Capacity
- 13 or 25 capillaries per batch
- 5 to 8 µL of sample required per capillary
ExperimentCrossFlowFiltration[]
Example applications include: Ultrafiltration, Microfiltration, Diafiltration, Protein Purification, Tangential Flow Filtration, Buffer Exchange, Desalting
Tangential Flow Filtration System
- Volume range of 10 mL to 2 L
- Filtration area of 13 to 3,700 cm²
- Digitally controlled peristaltic pump
- Digital pressure monitor
- Automatic backpressure valve
- Digital conductivity monitors
- Absorbance monitor of 200 to 800 nm
- UV-Vis spectrometer
- 200 to 1,100 nm wavelength range
- CCD detector allows the entire wavelength
- Sub-nanometer resolution
- Up to 200 measurements/sec
ExperimentDialysis[]
Example applications include: Fragile Proteins, Viscous Fluids, Polymer Gels, Equilibrium Dialysis, Small Molecule Binding to Proteins, Purification, Buffer Exchange, Desalting, Protein Purification
Static Dialysis
Beakers Available
- 250 mL, 600 mL, 1 L, and 2 L
- Incubation range 5 to 45°C (below ambient temperatures available for 250 mL beakers only)
- Buffer mixing available
Tube-Based Dialysis Kits
- 3.5k, 6 to 8k and 12 to 14k molecular weight cutoffs (MWCOs) available
- 10 µL to 20 mL sample volume range
- 4 to 60°C incubation range
- Up to 9 samples per batch
Dialysis Tubing
- 3.5k, 6 to 8k, and 12 to 14k MWCOs available
- 30 to 130 mL sample volume range
- Continuous buffer flow to increase separation efficiency
- 1 sample per batch
Equilibrium Dialysis
- 8 MWCO available
- 50 to 500 µL sample volume range
- 4 to 60°C incubation range
- Up to 48 samples per batch
Dynamic Dialysis
- 3.5k, 6k, and 12k MWCOs available
- 30 to 130 mL sample volume range
- Continuous buffer flow to increase separation efficiency
- > 90% protein recovery after dialysis
- 1 sample per batch
ExperimentThinLayerChromatography[]
High Performance TLC System (HPTLC)
Derivatization
- Automated micro-droplet spraying of chemical stains
- Application of aqueous or organic solutions
- Spot-to-spot relative standard deviation <5%
Application
- Up to 15 samples per HPTLC plate (20 x 10 cm)
- 5 to 6µm silica particle size
- Samples applied to plates as 8 mm bands for HPTLC
- Samples applied as spots for reaction monitoring
Development
- Gas phase can be actively controlled to ensure saturation of elution chamber
- Solvent front monitoring and automatic plate removal
- Development of TLC and HPTLC plate up to 20×20 cm
Visualization
- UV (254 and 366 nm) and white light illumination
- Visualize TLC and HPTLC plates up to 20×20 cm
- Rf evaluation and comparison within or between plates
- Semi-quantitative peak integration
ExperimentLiquidExtraction[]
Phase Separator
- Rapidly separates immiscible mixtures of organic and aqueous solutions via filtration
- Separation does not depend on whether the aqueous layer is on the top or bottom
- Up to 70 ML capacity per filtration
- Organic solvent flow rate up to 15 mL/min
Separatory Funnel
- Collects aqueous and organic layers of an immiscible mixture at a volume range of 10 mL to 1 L
Robotic Extraction
- Separate top layer from bottom layer given exact height of the top and bottom layer
- Control aspiration flow rate
ExperimentMagneticBeadSeparation[]
Example applications include: Magnetic Cell Separation, Protein Purification, Immunoprecipitation, Nucleic Acid Isolation
Magnetic Racks
Robotic Separation
- Performed by a Hamilton liquid handler with the Alpaqua Magnum FLX magnet
- Sample volume constraints
- 96-well plate magnet: up to 2 mL
Manual Separation
- Performed by an operator with the DynaMag magnets
- Sample volume constraints
- 96-well plate magnet: up to 0.2 mL
- 2 mL tube magnet: up to 2 mL
- 15 mL tube magnet: up to 15 mL
- 50 mL tube magnet: up to 50 mL